What Equipment Is Used to Check Eyes? A Comprehensive Guide to Modern Eye Examination Devices
Routine eye exams are essential for detecting vision problems, monitoring eye health, and identifying systemic conditions early. But have you ever wondered what equipment eye doctors use to examine your eyes? In this guide, we explore the most commonly used diagnostic tools in ophthalmology and optometry clinics. Whether you’re preparing for an eye check-up or you’re a medical device provider, understanding these tools offers insight into the science of eye care.
1. Autorefractor/Auto-Keratometer
Purpose: Measures how light is changed as it enters your eye and determines a baseline prescription.
Used for: Detecting refractive errors such as myopia, hyperopia, and astigmatism.
Features: Fast, automated readings; Often combined with keratometry (measures corneal curvature)
2. Phoropter
Purpose: Fine-tunes the eyeglass or contact lens prescription.
Used for: Subjective refraction testing.
How it works: Patients look through different lenses and report which ones make vision clearer.
Need measures of sphere, cylinder, and axis for accurate prescriptions.
3. Retinoscope
Purpose: Assesses how light reflects from the retina.
Used for: Objective measurement of refractive error, especially helpful for children or non-verbal patients.
Advantages: Simple yet highly effective; Often used in conjunction with manual refraction
4. Slit Lamp Microscope
Purpose: Provides a magnified view of the front and internal structures of the eye.
Used for: Examining the cornea, iris, lens, and anterior chamber; Diagnosing cataracts, corneal ulcers, and infections; Typically used with.
5. Tonometer
Purpose: Measures intraocular pressure (IOP).
Used for: Glaucoma screening and monitoring.
Types:
Non-contact tonometer (air puff): quick and comfortable
Applanation tonometer (Goldmann): more accurate, used with a slit lamp
6. Ophthalmoscope (Fundoscope)
Purpose: Allows examination of the retina and optic nerve.
Used for: Detecting retinal detachment, diabetic retinopathy, optic neuritis, and more.
Types:
Direct ophthalmoscope: handheld, high magnification
Indirect ophthalmoscope: worn on the head, allows a wider view.
7. OCT (Optical Coherence Tomography) Scanner
Purpose: Produces cross-sectional images of the retina.
Used for: Diagnosing macular degeneration, glaucoma, and diabetic eye disease; Monitoring the progression of retinal diseases
Benefits:
Non-invasive and highly detailed imaging
Crucial in early disease detection
8. Visual Field Analyzer (Perimeter)
Purpose: Measures the range and sensitivity of a person’s peripheral vision.
Used for:
Detecting blind spots (scotomas)
Glaucoma progression analysis
Neurological assessments (e.g., stroke or tumor effects)
9. Fundus Camera
Purpose: Takes detailed images of the retina.
Used for:
Retinal screening and documentation
Diabetic retinopathy, AMD, and hypertension-related retinopathy
Advantage: Permanent record for comparison over time
10. Corneal Topographer
Purpose: Maps the surface curvature of the cornea.
Used for:
LASIK evaluations
Contact lens fitting
Keratoconus detection
Conclusion
From basic vision screenings to advanced imaging, eye exams rely on a wide array of highly specialized equipment. Each instrument serves a unique diagnostic purpose, collectively allowing eye care professionals to provide accurate assessments and early intervention. If you're a patient, knowing what to expect can reduce anxiety. If you're in the medical device or eye care industry, understanding these tools is essential for product education and marketing.
Recommended for you

FAQ
About Products
How long does it take to see results?
Patients with dry eye symptoms can get significant relief by wearing this product for a standard course of treatment (20 minutes/times), and it is recommended to use it by the full course of treatment (clinical data shows that about 87% of users feedback significant improvement in visual clarity after 2 weeks of continuous use).
About Company
What is the background of the R&D team?
The core team consists of experts from Zhongshan Ophthalmic Center and PhDs in optoelectronic engineering, and owns 15 patents related to visual rehabilitation.
Logistics and Customs Clearance
How to guarantee the breakage rate?
We promise that the defective rate will be ≥99.5%, otherwise, we will make up for the defective rate proportionally.
Customized Service (For OEM/ODM)
What is the minimum order quantity for ODM?
Hardware customization starts at 1000 units, and software UI customization starts at 100 units.
After-sales Support (For B2B Service)
How is the technical training implemented?
Online: Provide bilingual video tutorials and instruction manuals.
Offline: B-end customers can make an appointment with an engineer for on-site training. (travel expenses need to be borne.)
-
Contact Us for More Details
-
-
For custom designs, competitive pricing, or strategic partnerships, reach out to us. We'll get back to you promptly—usually within 24 hours.
-
© 2025 Skaphor. All Rights Reserved.
Whatsapp: +8618924224541
zhu Juliy
Skaphor_ Juliy